skip navigation
Back

Prosecution Details

Defendant Harvey Fresh (1994) Ltd
Trading Name Not Applicable
Regulation 607(1)(b) [1] and 607(1)(b) [2]
Offence Date Monday, 15 January 1996
Description of Breach(es)

[1] Kept classified plant, namely a boiler with plant identification number 39575, that was capable of being used, without a Certificate of Inspection being in force for that item of plant.

[2] Used classified plant, namely a boiler with plant identification number 35236, without a Certificate of Inspection being in force for that item of plant.

Background Details

The premises were inspected with the view of determining the inspection and certification status of their two steam boilers. Upon asking to see the current certificates of inspection for the two boilers, or records to indicate that the boilers had been inspected since the expiry of the previously issued certificates, Harvey Fresh could not provide certificates nor show records to indicate that the boilers had recently been inspected. WorkSafe's records showed that certification of boiler 39575 had expired on 13 September 1995 and certification of boiler 35236 had expired on 16 November 1995.




Outcome Summary convicted
Conviction Date 06 Oct 1997
Court Harvey Court of Petty Sessions
Fine $500 [1] and $500 [2]
Costs $275 [1] and $275 [2]
Charge Number Not available